Abstract

Earthquake never kills people but the defective structures do. The stability and stiffness of any structure is the major issue of concern in any high rise buildings. Shear walls are structural members which resist lateral forces predominant on moment resisting frame. Shear walls are most preferred structural walls for earthquake resistance. This research is related to comparison of shear wall type structure with moment resisting type of building. The present study states three type of models, moment resisting frame i.e. model 1, Shear wall building concentrically located along X- axis on outer periphery of building i.e. model 2, and Concrete column flange concentrically located on outer periphery along the X-axis i.e. model 3. Models of the three structures with same loading were created on STAAD-Pro and were analyzed and further they where compared for their suitability. For 10 storey building and 3 bays along X-axis of 4m each and 4 bays along Z-axis of 4m each were considered and loads were applied as per the IS specifications. The analysis was conducted as per the specifications of IS standards IS 13920, IS 1893, IS 875, IS 456. From the result it is seen that there is decrease of approximately 10% in Lateral storey shear and Base shear when the moment resisting frame was introduced with shear wall.

References

B. Ramamohana Reddy, M. Visweswara Rao, “Earthquake resistant design of a building using shear wall”. IJMETR, Volume no: 2 (2015), Issue no: 10,

October 2015, ISSN no: 2348-4845.

P. P. Chandurkar, Dr. P. S. Pajgade, “Seismic analysis of RCC Building with and without shear wall”. IJMER, Vol.3, Issue 3, May-june 2013,pp-1805-1810,2013.

Manoj S. Medhekar, Sudhir K. Jain, “Seismic behaviour design and detailing of RC shear wall, Part 1: Behaviour and Strength” . The Indian Concrete Journal, July 1993.

Venkata Sairam Kumar.N, Surendra Babu.R, Usha Kranti.J, “ Shear Wall- A Review”. IJIRSET, Vol. 3, Issue 2, February 2014, ISSN: 2319-8753.

Bhruguli H. Gandhi, “Effect of opening on behaviour of shear wall”. IJTRE, Volume 3, Issue 4, December-2015, ISSN: 2347 – 4718.

S. M. Khatami, A. Kheyroddin “The Effect of Flange Thickness on the Behavior of Flanged- Section Shear Walls”. ELSEVIER, Procedia Engineering 14 (2011) 2994–3000.

Shyam Bhat M, N. A. Premanand Shenoy, Asha U Rao, “Earthquake behaviour of buildings with and without shear walls”. IOSR-JMCE, e-ISSN: 2278-1684,

p-ISSN: 2320-334X PP 20-25.

Vinoth Kumar M, Ramesh B, Senthil Kumaran N.S, “Influence of Shear Wall and Coupling Beam Dimensions on Seismic Behaviour”. JCHPS Special, Issue 6, November 2016, ISSN: 0974-2115.

Vishal A. Itware, Dr. Uttam B. Kalwane, “Effects of Openings in Shear Wall on Seismic Response of Structure”. IJERA, Vol. 5, Issue 7, (Part - 1) July 2015, pp.41-45, ISSN : 2248-9622

S.Saileysh Sivaraja, S. Sengolmurugan, Seismic Behavior of Structures with Moment Resisting Frame (MRF) and Shear Wall (SW) IJTRD, Volume 4(1), Jan-Feb 2017, ISSN: 2394-9333.

C. V. R. Murty, Rupen Goswami, A. R. Vijayanarayanan, Vipul V. Mehta, “Earthquake Behaviour of Buildings”. GSDMA, Govetnment of Gujarat, September 2012.

Downloads

Published

2018-03-30

How to Cite

Chauvhan, K., Bhondhle, S., Rajput, S., Shivhare, A., Gedam, M., & Thakur, A. kumar M. (2018). A RESEARCH ON COMPARING THE EFFECT OF EARTHQUAKE ON HIGH RISE BUILDINGS WITH SHEAR WALL, WITHOUT SHEAR WALL AND FLANGED CONCRETE COLUMN. Universal Research Reports, 5(4), 40–53. Retrieved from https://urr.shodhsagar.com/index.php/j/article/view/718

Issue

Section

Original Research Article