A REVIEW ON PERFORMANCE ANALYSIS OF NATURAL AND INDUCED DRAFT COOLING TOWER IN SUMMER AND MONSOON SEASONS

Authors

  • Dwivedi G
  • Vishwakarma R ndore (M.P.), India (An institution affiliated to Rajiv Gandhi ProudyogikiVishwavidyalaya (RGPV), Bhopal (M.P.), India).

Keywords:

Power Plant, Cooling Tower

Abstract

Power plants, some other industries produce a large quantity of waste heat in the form of hot water. In the present scenario, in most of the places, the water supply is limited and thermal pollution is also a serious concern.Cooling tower is an integral part thermal power generation plant. A cooling system may be a heat rejection device that rejects waste heat to the atmosphere through the cooling of a water stream to a lower temperature. Cooling towers are used in all heat producing industries. Power plants, some other industries produce a large quantity of waste heat in the form of hot water.Temperature and humidity inside the tower are having main influence on the performance of natural draft cooling tower.

References

A. Kumar, H. Banothu, M. Dilawar, and M. Kumar, “Analysis of performance of natural draft cooling tower at optimized injection height,” Int. J. Mech. Eng. Technol., vol. 9, no. 7, pp. 687–694, 2018.

P. R. Chitale, R. K. Gamare, S. K. Chavan, R. Suresh, and A. S. Yekane, “Design and Analysis of Cooling Tower,” J. Eng. Res. Appl., vol. 8, no. 4, pp. 79–84, 2018.

V. S. Kumar and R. Mathews, “Performance Analysis and Optimization of Cooling Tower,” Int. J. Sci. Res. Publ., vol. 8, no. 4, pp. 225–237, 2018.

C. N. Nataraj, “Study on Induced Draft Cooling Tower Performance Analysis in Captive Power Plant,” Int. Res. J. Eng. Technol., vol. 4, no. 8, pp. 414–421, 2017.

K. S. Vishwakarma et al., “Study the factors on which efficiency of cooling tower can be critically acclaimed (A case Study),” J. Eng. Res. Appl. Www.ijera.com ISSN, vol. 5, no. 43, pp. 2248–962273, 2015.

. M. Variava, “PERFORMANCE ANALYSIS OF COOLING TOWER IN PROCESS INDUSTRY,” no. 6, pp. 1722–1730, 2017.

M. V. . Satish Kumar, “Performance Analysis of Cooling Tower,” Int. J. Eng. Trends Technol., vol. 38, no. 8, pp. 442–448, 2016.

P. Ajit, P. Dash, K. K. Panda, A. K. Yadav, and V. Sharma, “Design of mechanical draftcooling tower and determination of thermal efficiency,” vol. 1, no. 4, pp. 191–197, 2016.

S. Kulkarni and A. Goswami, “Studies and Experimentation on Cooling Towers: A Review,” Int. Res. J. Eng., pp. 279–282, 2015.

J. H. Alsuwaidi, O. R. Al Hamdan, and M. M. I. Hammad, “Natural Draft Cooling Tower Performance Evaluation,” vol. 6, no. 4, pp. 1499–1512, 2015.

P. V Dave, “Thermal Performance Analysis of Natural Draft Cooling Tower Simulation using CFX,” vol. 3, no. 1, pp. 1–4, 2015.

Shashank Tiwari and Prof. Mahendra Agrawal, “Analysis of Counter Flow Induced Draft Cooling Tower using Taguchi Method,” Int. J. Eng. Res., vol. V4, no. 06, pp. 292–297, 2015.

E. Journal, S. A. Ahmad, A. Ahmad, A. Butt, and T. Waqas, “Performance Improvement of Mechanical Induced Draft Cooling Tower by Using Aluminum as Fill Medium,” vol. 3, no. 11, pp. 10–14, 2016.

B. S. Pushpa, V. Vaze, and P. T. Nimbalkar, “Performance Evaluation of Cooling Tower in Thermal Power Plant - A Case Study of RTPS , Karnataka Different Radius Vs Loss of Temperature,” no. 2, pp. 110–114, 2014.

R. M. A, “Performance Improvement of Natural Draft Cooling Tower,” Int. J. Eng. Res. Rev., vol. 2, no. 1, pp. 7–15, 2014.

T. Jagadeesh, “Performance Analysis of the Natural Draft Cooling Tower in Different Seasons,” IOSR J. Mech. Civ. Eng., vol. 7, no. 5, pp. 19–23, 2013.

B. B. Sai, I. Swathi, K. S. L. Prasanna, and S. Rao, “Design of Cooling Tower,” Int. J. Sci. Eng. Res., vol. 4, no. 5, pp. 1560–1563, 2013.

R. Ramkumar, A. Ragupathy, “Thermal Performance Of Forced Draft Counter Flow Wet Cooling Tower With Expanded Wire Mesh Packing”, International Journal On “Technical And Physical Problems Of Engineering” , vol. 3, no. 1,pp.19-24, Mar. 2011.